DP1541, OS1541 Superseded Product
Two-Color I/R System. Rack Mounted Monitor

DP1541, OS1541 <font color=#cc0000>Superseded Product</font> : Two-Color I/R System. Rack Mounted Monitor
Kliknģte zde pro vģtšķ obrįzek.
  Exceptional for Induction Heating
  Measurements Independent of Emissivity
  Optional Signal Processing
  Optional Controller Outputs
  1 mV/Degree Output Standard
  Optional 0-10 Vdc, 4-20 mA Linear Second Output
  Switchable 10 or 100 msec Time Constant

OS1542 Sensors

  Silicon Detector
  0.9 and 1.06 Micron Filters
  Temperatures from 980 to 1800°C
  Minimal Effect by Steam or Hot Gas

OS1543 Sensors

  Lead Sulfide Detector
  1.55 and 2.25 Micron Filters
  Temperatures from 250 to 1500°C

The OS1540 Series has been superseded, please see the OS4000 Series as a possible substitute or consult OMEGA's Temperature Engineering department.

The OS1542 and OS1543 fiber optic sensors are designed specifically for the DP1541 two-color emissivity-independent monitor and the associated fiber optic cable assembly. The small size of these probes makes them well suited for installations with limited mounting room. They are unaffected by RFI and EMI noise, which also make them excellent for use in hostile environments like induction or microwave heating.

The OS1542 and OS1543 fiber optic sensors operate at two wavebands and utilize an energy ratio to calculate temperature. They can, therefore, measure temperature on objects whose emissivity is unknown provided the emissivity at all temperatures is proportional at the two wavebands used for the measurement, which is typical.

The OS1542 fiber optic sensor head has a silicon detector filtered at narrow bands centered at 0.90 and 1.06 microns; it is used primarily at high temperatures and is minimally affected by steam and hot gas.

The OS1543 fiber optic sensor head has a lead sulfide detector filtered over wide bands centered at 1.55 and 2.25 microns. It is used as a general purpose head which can measure temperatures down to 250°C. It should not be used where hot steam or gas is present.

The fiber optic cable assembly differs according to certain parameters specific to the application. It allows remote mounting of the OS1542 or OS1543 detector heads away from hot or hazardous areas.

        
IR2 SUPERMETER® Ultra High Performance 2-Color Ratio Fiber Optic Infrared Temperature Measurement and Control System          Fast Response Infrared Fiber Optic Thermometer/Transmitter with Local Display and Analog Output

CLICK HERE !
        
CLICK HERE !


 Čķslo modelu  Cena (bez DPH)  Popis  Ks
 DP1541-F   Kontaktujte prodejce  Single channel 19" rackmount two-color monitor, slope control, 1 mV/ degree output, 3 3 /4 digit display. (For use with OS1542 or OS1543 sensors.) Analog Output 1 mV/°F
 DP1541-C   Kontaktujte prodejce  Single channel 19" rackmount two-color monitor, slope control, 1 mV/ degree output, 3 3 /4 digit display. (For use with OS1542 or OS1543 sensors.) Analog Output for 1 mV/°C.
 OS1542-L1-R1-4   Kontaktujte prodejce  Optical Sensor 1050-1800°C (1925-3270°F) Spot Size @ Focal Dist. 1.2" @ 36" 4ft. Cable Length.
 OS1542-L1-R2-4   Kontaktujte prodejce  Optical Sensor 980-1650°C (1850-3000°F) Spot Size @ Focal Dist. 0.18" @ 14", 4ft. Cable Length.
 OS1543-L1-R3-4   Kontaktujte prodejce  Optical Sensor 450-850°C (847-1562°F), Spot Size @ Focal Dist. (0.076" @ 6"), Cable Length 4 ft.
Obsah košķku Vyprįzdnit košķk Objednat
 * využijte možnost konzultovat ceny pųķmo s našimi prodejci  (tel: 596 311 899 - prodejnķ oddģlenķ, e-mail: viz. kontaktnķ informace)
 Poznįmka: Each unit supplied with complete operator’s manual. Consult OMEGA for information on many other controller configurations.

(1) (2) (3)
DP1541-
Popis voleb
(1) Analog Output
  Vyberte F pro 1 mV/°F, C pro 1 mV/°C
(2) Second Output
  Vyberte prįzdné pole pro Standard Unit, -V pro 0 to 10 Vdc, -MA pro 4 to 20 mA
(3) Signal Processing Outputs
  Vyberte prįzdné pole pro Standard Unit, -PS pro Peak sense and Hold, -SA pro Signal Averaging, -VS pro Valley Sense and Hold, -ST pro Sample Timed Hold, -FR pro Fast Rise Variable Decay
 Poznįmka: ne všechny kombinace jsou sprįvné, ovģųte si sprįvnost čķsla modelu.

 Literatura
   Stįhnout kompletnķ specifikace produktu ve formįtu PDF