DP2000-JKT Series
Thermocouple Meters, Indicators/Controllers
1/8 DIN

DP2000-JKT Series : Thermocouple Meters, Indicators/Controllers<br>1/8 DIN
Kliknìte zde pro vìtší obrázek.

11,700.00  Kč *
     DP2000-K1

  -300 to 1999 or 9999 Count Display Span
  Thermocouple Types J, K, and T
  3-1/2 or 4-Digit Display
  1° or 0.1° Resolution
  Internal Reference Junction
  Sensor-Break Detection
  1 or 0.1 mV/Count Linearized Analog Output
  LED or LCD Display
  Display Hold and Test
  Screw-Terminal Barrier Strip

The DP2/9000-J, DP2/9000-K and DP2/9000-T are indicator/controllers for thermocouple Types J, K and T, respectively. They are complete with linearization, coldjunction compensation, and sensor-break detection. Readout is in °C or °F with 1° or 0.1° resolution.

POWER AND DISPLAY OPTIONS
Six types of power supplies are available: 120 Vac, 240 Vac, 24 Vac, 5 Vdc, isolated 9 to 32 Vdc and isolated 26 to 56 Vdc. A LED display is standard, an LCD display is optional and is recommended for viewing in bright ambient light. A NEMA 4 (IP65) splash-proof lens cover is available.

Signal input and power connections are made via a rear barrier terminal strip. The motherboard rear edge connector provides access to hold and test, polarity, clock, and the standard analog output and optional analog outputs.

ANALOG OUTPUT OPTIONS
A 1 mV/count or 0.1 mV/count (±2 V full-scale) analog output is standard and is useful for driving a strip-chart recorder. An additional analog output can be provided by an optional vertical plug-in board. Available output signals are 0 to 5 Vdc, 0 to 10 Vdc, 0 to 1 mA (source or sink), and 4 to 20 mA (source or sink). The top and bottom of each output range can be scaled to fit a user-selected display span.

CONTROL OUTPUT OPTIONS
Additional outputs can be provided by a horizontal upper board. Available options include single-setpoint control with one 10 A relay, dualsetpoint control with two 10 A relays, 4 to 20 mA proportional control (source or sink), time-proportional 2 A solid-state relay control, and isolated, parallel BCD output.

SPECIFICATIONS
Analog Input
TC Types: J, K, T
Calibration: To IPTS-68, as published in NIST monograph 125 (March 1974), ASTM E130-72 or ASA C96.2-1973
Configuration: Single-ended (-TC lead connected to ANA GND)
Input Resistance: 100 MΩ
Sensor-Break Detection: 400 nA current source Max Lead Resistance for Rated
Accuracy: 500 Ω (Type J), 395 Ω (Type K), 200 Ω (Type T)
Zero Tempco (cold-junction error): ±0.06 degree/degree
Span Tempco, 10 to 40°C: ±0.01% of reading/°C Analog-To-Digital Conversion
Input Configuration: Single-ended SIG HI (TC + ) lead connected to SIG GND through 10 Ω
Display
Symbols: -1.8.8.8 (DP2000); 8.8.8.8 (DP9000)
LED: Red, 14.2 mm (0.56"), 7-segment
LCD: 12.7 mm (0.50"), 7-segment
Power
AC Models: 120, 240 or 24 Vac, +10/ -15%, 49 to 440 Hz
DC Models: 5 Vdc ±5%, 9 to 32 Vdc or 26 to 56 Vdc isolated to 300 Vp
Common Mode
Voltage: 1500 Vp test (354 Vp per IEC spacing)
Rejection: 120 dB with 250 Ω imbalance
Environmental
Operating Temperature: 0 to 60°C (32 to 140°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Humidity: 95% RH, non-condensing @ 40°C (104°F)
Mechanical
Bezel: 96 W x 48 H x 8 mm D (3.78 x 1.89 x 0.31")
Depth Behind Bezel: 139.8 mm (5.50")
Panel Cutout: 92 W x 45 mm H (3.62 x 1.77")
Weight: 17 oz (480 g)
Case material: 94V-0 UL-rated polycarbonate


 Èíslo modelu  Cena (bez DPH)  Popis  Ks
 DP2000-J2    11,700.00 Kč   3-1/2 digit meter, red LED display, 120 Vac power, 1 mV per count analog output, type J thermocouple input with -40 to 760°C range
 DP2001-J2    16,800.00 Kč   3-1/2 digit meter, red LED display, 120 Vac power, 1 mV per count analog output, dual setpoint 10A relay, type J thermocouple input with -40 to 760°C range
 DP2005-K2    16,200.00 Kč   3-1/2 digit meter, red LED display, 120 Vac power, 1 mV per count analog output, single setpoint 10A relay, type K thermocouple input with -40 to 1260°C range
 DP2001-T2    17,400.00 Kč   3-1/2 digit meter, red LED display, 120 Vac power, 1 mV per count analog output, dual setpoint 10A relay, type T thermocouple input with -184 to 371°C range
 DP9000-T1   Kontaktujte prodejce  4 digit meter, red LED display, 120 Vac power, 1 mV per count analog output, type T thermocouple input with -184.0 to 371.0°C range
Obsah košíku Vyprázdnit košík Objednat
 * využijte možnost konzultovat ceny pøímo s našimi prodejci  (tel: 596 311 899 - prodejní oddìlení, e-mail: viz. kontaktní informace)
 Poznámka: Comes complete with operator’s manual.
 Pøíklad objednávky: (1) DP2005-K2 3-1/2 digit, red LED, 120 Vac power, 1 mv/count, single setpoint 10 A relay, Type K, -40 to 1260°C range., (1) DP2101-K1 3-/12 digit, LED, 120 Vac power, 1°C/count, dual setpoint (10 A relay), Type K -40 to 1260°C range,  = 34,500.00 Kč

(1) (2) (3) (4) (5) (6)
DP -
Popis voleb
(1) Display Resolution and Case Style
  Vyberte 2 pro ±1999 counts (3 1/2 digits), 9 pro ±9999 counts (4 digits)
(2) Display & Power Options
  Vyberte 0 pro LED 120 Vac (49/440 Hz) (BQ20 or BQ90), 1 pro LCD 120 Vac (49/440 Hz) (BQ21), 2 pro LED 240 Vac (49/440 Hz) (BQ22 or BQ92), 3 pro LCD 240 Vac (49/440 Hz) (BQ23), 4 pro LED 9-32 Vdc (isolated) (BQ24 or BQ94), 5 pro LCD 9-32 Vdc (isolated) (BQ25), 6 pro LED 5 Vdc** (BQ26 or BQ96), 7 pro LCD 5 Vdc** (BQ27), 8 pro LED 24 Vac (BQ28 or BQ98), 9 pro LCD 24 Vac (BQ29) , A pro LED 26-56 Vdc (isolated) (BQ2A or BQ9A), B pro LCD 26-56 Vdc (isolated) (BQ2B)
(3) Analog Outputs
  Vyberte 0 pro 1mV/count (DP2) or 0.1mV/count (DP9) analog output (standard), 1 pro 0-5 Vdc non-isolated (BA01) , 2 pro 0-10 Vdc non-isolated (BA01), 3 pro 0-1 mA source or sink non-isolated (BA01) , 4 pro 4-20 mA source or sink non-isolated (BA01), 5 pro 4-20 mA sink (high-compliance) non-isolated. (BA02), 6 pro 4-20 mA ISOLATED (BA03)
(4) Control Outputs
  Vyberte 0 pro None, 1 pro Dual-setpoint 10 A relay. (BDT1), 2 pro Proportional 4-20 mA control source or sink (BDP1), 3 pro Time-proportional solid-state 2 A relay plus proportional 4-20 mA control source or sink. (BDP2) , 4 pro BCD (isolated latched buffered byte addressable). Includes 50-pin mass-termination connector. (BDD2) , 5 pro Single-setpoint 10 A relay (BDS1)
(5) Input Type and Range
  Vyberte J1 pro Type J Thermocouple input -40 to 760°C (DP2000) or -40.0 to 760.0°C (DP9000) (BSCJ), J2 pro Type J Thermocouple input -40 to 1400°F (DP2000) or -40.0 to 999.9°F (DP9000) (BSCJ), K1 pro Type K Thermocouple input -40 to 1260°C (DP2000) or -40.0 to 999.9°C (DP9000) (BSCK), K2 pro Type K Thermocouple input -40 to 1999°F (DP2000) or -40.0 to 999.9°F (DP9000) (BSCK), T1 pro Type T Thermocouple input -184 to 371°C (DP2000) or -184.0 to 371.0°C (DP9000) (BSCT), T2 pro Type T Thermocouple input -300 to 700°F (DP2000) or -300.0 to 700.0°F (DP9000) (BSCT)
(6) Display Color
  Vyberte prázdné pole pro for Red Display (standard), -G pro Green Display
 Poznámka: ne všechny kombinace jsou správné, ovìøte si správnost èísla modelu.

 Literatura
   Stáhnout kompletní specifikace produktu ve formátu PDF