DRF-TC Series
Thermocouple Input Signal Conditioner

DRF-TC Series : Thermocouple Input Signal Conditioner
Kliknėte zde pro vėtší obrázek.

5,850.00  Kč *
     DRF-TCE-115VAC-0/800C-4/20

  Models for J, K, E, T, R and S Thermocouples
  Accuracy 0.3%
  250 ms Response Time
  Upscale Break Protection
  Linearized Output
  Galvanic Isolation Between Input, Output and Power

The DRF series DIN rail signal conditioners are designed to accept a broad range of input signals, such as ac and dc voltage and current, frequency, temperature (thermocouple and RTD), and process transducers, and provide standard process outputs of either 4 to 20 mA, or 0 to 10 Vdc. The DRF series feature a modern housing design, that is easily mounted on standard 35 mm DIN rails. Connections are safely and securely made through pluggable screw terminal connectors, with input and output connections on the opposite sides of the module.

The DRF-TC thermocouple signal conditioners accept thermocouple input and provide a linearized and isolated 0 10 Vdc or 4 to 20 mA output. Models are available with three different power options, 24Vdc, 120 Vac and 240 Vac.

The DRF-TC are ideally suited for industrial applications. All models mount on a standard 35 mm DIN rail and provide galvanic isolation between input, output and power up to 3500 Veff (model specific). To insure maximum measurement accuracy the units feature cold junction compensation, 0.2% linearity and less than 0.1°C/1°C thermal drift due to compensation. Module response time is 250 ms or less.

Range Code Table for DRF-TC
Range CodeRangeJKTERS
0/100°C0 to 100°C   X  
0/150°C0 to 150°CXX    
0/175°C0 to 175°C   X  
0/200°C0 to 200°C  X   
0/250°C0 to 250°CXX    
0/300°C0 to 300°C  XX  
0/400°C0 to 400°CXXX   
0/500°C0 to 500°C   X  
0/700°C0 to 700°CXX    
0/800°C0 to 800°C   X  
0/1200°C0 to 1200°C X    
0/1600°C0 to 1600°C     X
850/1700°C850 to 1700°C    X 
Minimum Span* 85°C85°C100°C85°C100°C100°C
* Custom ranges may be obtained by adjusting on-board zero and span potentiometers.
The minimum range is limited by the minimum span specification.


SPECIFICATIONS

Accuracy: <0.3% full scale
Linearity: <0.2% full scale
Thermal Drift: 250 ppm/°C typical
Thermocouple CJC Drift: 0.1°C/°C
Response Time: <250 mS (90% of signal)
Power: 24 Vdc ±10%, 230 Vac ±10% 50/60 Hz, 115 Vac ±10% 50/60 Hz
Power Consumption: <3.8 VA

Output: 4 to 20 mA and 0 to 10 Vdc
Maximum Voltage Output: 11 Vdc approx.
Minimum Voltage Output: -1 Vdc approx.
Minimum Load Resistance (Voltage): >1 KΩ Maximum Current Output: 22 mA approx.
Maximum Current Output: -1.5 mA approx.
Maximum Load Resistance (current): >400 Ω
 

Electrical Connections: Plug-in screw terminals
Protection: IP-30

MECHANICAL DIMENSIONS
Weight:
(DC Powered Models): 120 g (4.2 oz)
(AC Powered Models): 200 g (7 oz)
Dimensions:
(DC Powered models):
110 H x 22.5 W x 93 mm D (4.3 x 0.9 x 3.7")
(AC Powered models):
110 H x 37 W x 93 mm D (4.3 x 1.46 x 3.7")
Operating Temperature: 0 to 60°C (32 to 140°F)
Storage Temperature: -20 to 70°C (-4 to 158°F)


 Číslo modelu  Cena (bez DPH)  Popis  Ks
 DRF-TCE-115VAC-0/100C-4/20    5,850.00 Kč   Type E thermocouple signal conditioner with 0 to 100°C range, 4 to 20mA output and 115Vac power
 DRF-TCE-115VAC-0/800C-4/20    5,850.00 Kč   Type E thermocouple signal conditioner with 0 to 800°C range, 4 to 20mA output and 115Vac power
 DRF-TCJ-115VAC-0/400C-4/20    5,850.00 Kč   Type J thermocouple signal conditioner with 0 to 400°C range, 4 to 20mA output and 115Vac power
 DRF-TCJ-115VAC-0/700C-4/20    5,850.00 Kč   Type J thermocouple signal conditioner with 0 to 700°C range, 4 to 20mA output and 115Vac power
 DRF-TCK-115VAC-0/1200C-4/20    5,850.00 Kč   Type K thermocouple signal conditioner with 0 to 1200°C range, 4 to 20mA output and 115Vac power
 DRF-TCK-115VAC-0/400C-4/20    5,850.00 Kč   Type K thermocouple signal conditioner with 0 to 400°C range, 4 to 20mA output and 115Vac power
 DRF-TCT-115VAC-0/200C-4/20    5,850.00 Kč   Type T thermocouple signal conditioner with 0 to 200°C range, 4 to 20mA output and 115Vac power
Obsah košíku Vyprázdnit košík Objednat
 * využijte možnost konzultovat ceny pøímo s našimi prodejci  (tel: 596 311 899 - prodejní oddėlení, e-mail: viz. kontaktní informace)
 Pøíklad objednávky: (1) DRF-TCJ-115VAC-0/400C-4/20 Type J thermocouple signal conditioner with 0 to 400°C range, 4 to 20mA output and 115Vac power = 5,850.00 Kč

(1) (2) (3) (4)
DRF-TC - - -
Popis voleb
(1) Thermocouple Type
  Vyberte J pro J thermocouple, K pro K thermocouple, T pro T thermocouple, E pro E thermocouple, R pro R thermocouple, S pro S thermocouple
(2) Power
  Vyberte 115VAC pro 115 Vac power, 230VAC pro 230 Vac power, 24VDC pro 24 Vdc power
(3) Range Code
  Vyberte 0/100C pro 0 to 100°C (E thermocouple only), 0/150C pro 0 to 150 degree C (K thermocouple only), 0/175C pro 0 to 175 degree C (E thermocouple only), 0/200C pro 0 to 200 degree C (T thermocouple only), 0/250C pro 0 to 250 degree C (K thermocouple only), 0/300C pro 0 to 300 degree C (T and E thermocouple only), 0/400C pro 0 to 400 degree C (K and T thermocouple only), 0/500C pro 0 to 500 degree C (E thermocouple only), 0/700C pro 0 to 700 degree C (J and K thermocouple only), 0/800C pro 0 to 800 degree C (E thermocouple only), 0/1200C pro 0 to 1200 degree C (K thermocouple only), 0/1600C pro 0 to 1600 degree C (S thermocouple only), 850/1700C pro 850 to 1700 degree C (R thermocouple only)
(4) Output
  Vyberte 4/20 pro 4 to 20 mA, 0/10 pro 0 to 10Vdc
 Poznámka: ne všechny kombinace jsou správné, ovėøte si správnost čísla modelu.

 Literatura
   Stáhnout kompletní specifikace produktu ve formátu PDF
 Manuály
   Stáhnout  DRF-TCJ, DRF-TCK, DRF-TCT, DRF-TCE, DRF-TCR, and DRF-TCS Series - Thermocouple Input Modules
 Souvísející odkazy
   DRF-FR: DRF-FR Freqency Input Signal Conditioner
   DRF-IDC and DRF-IAC: DC and AC Current Input Signal Conditioners
   DRF-LC: DRF-LC Load Cell Input Signal Conditioner
   DRF-PR: DRF-PR Process Input Signal Conditioners
   DRF-RES and DRF-POT: Resistance and Potentiometer Input Signal Conditioners
   DRF-VDC and DRF-VAC: DC and AC Voltage Input Signal Conditioners