DRSL-RTD-LP
RTD Input Non-Isolated DIN Rail Loop-Powered Signal Conditioner

DRSL-RTD-LP : RTD Input Non-Isolated DIN Rail Loop-Powered Signal Conditioner
Kliknėte zde pro vėtší obrázek.

2,550.00  Kč *
     DRSL-RTD-LP

  2, 3 or 4-Wire Pt100 RTD Input
  Powered By the Host (Output) Current Signal Loop
  High Accuracy Better Than 0.2°C or 0.1% of Selected Range
  Slimline 6 mm (0.24") Housing
  Excellent EMC Performance and 50/60 Hz Noise Suppression
  Fast Response Time < 30 ms/300 ms (Selectable)
  Pre-Calibrated Temperature Ranges Selectable via DIP-Switches

The DRSL-RTD-LP RTD input non-isolated DIN rail loop-powered signal conditioner measures a standard 2-, 3- or 4-wire Pt100 temperature sensor and provides a passive analog current output signal. The DRSL-RTD-LP provides a competitive choice in terms of both price and technology for interfacing RTD signals to SCADA systems or PLC equipment. This unit is powered by the host (output) current signal loop. Low power consumption facilitates DIN rail mounting without the need for any air gap. Easy configuration of more than 1000 factory calibrated measurement ranges is done via DIP-switches. The unit operates over a wide temperature range from -25 to 70°C (-13 to 158°F).

SPECIFICATIONS
INPUT
Input Type: 2, 3, or 4-wire Pt100 RTD
Temperature Range: -200 to 850°C (-328 to 1562°F)
Sensor Current, RTD: <150 µA
Sensor Cable Specifications: 50Ω per wire or 50 nF
Effect of Sensor Cable Resistance (3 or 4-Wire RTD): <0.002Ω/Ω
Broken Sensor Detection: >800Ω
Shorted Sensor Detection: <18Ω

OUTPUT
Current Output
Programmable Signal Ranges: 0 to 20 mA and 4 to 20 mA
Range Limits (NAMUR NE43 Out of Range): Below 3.8 mA or above 20.5 mA
Sensor Error Detection (Dip Switch Selectable for Enable or None): Below 3.5 mA or above 23 mA
Incorrect DIP-Switch Setting Identification: Below 3.5 mA or above 23 mA
Output Error Level: DIP switch selectable for upscale or downscale
Load Resistance (Ω): ≤(Vsupply -3.3)/ 0.023
Load Stability: ≤0.01% of span/100Ω

GENERAL
Supply Voltage: 3.3 to 35 Vdc
Voltage Drop: 3.3 Vdc
Power Consumption: 1 W max
Internal Consumption: 0.65 W max
Signal/Noise Ratio: >60 dB
Response Time (0 to 90%, 100 to 10%): <30 ms/300 ms (selectable, provides either fast response or signal dampening as needed).
Accuracy: Better than 0.2°C or ±0.1% of selected range
Temperature Coefficient: ≤±0.02°C/°C
EMC Immunity Influence: <±0.5% of span
Extended EMC Immunity
    NAMUR NE 21, A Criterion, Burst: <±1% of span (span = selected input range)

ENVIRONMENTAL
Operating Temperature: -25 to 70°C (-13 to 158°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Calibration Temperature: 20 to 28°C (68 to 82°F)
Relative Humidity: 0 to 95% RH non-condensing
Protection Degree: IP20
Installation Area: Pollution degree 2 and measurement/overvoltage category II

MECHANICAL
Dimensions: 113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5")
Weight: 70 g (0.15 lb) approx
DIN Rail Type: DIN EN 60715 - 35 mm
Wire Size: 0.13 x 2.5 mm²/AWG 26 to 12 stranded wire
Screw Terminal Torque: 0.5 Nm


 Číslo modelu  Cena (bez DPH)  Popis  Ks
 DRSL-RTD-LP    2,550.00 Kč   RTD input non-isolated DIN rail loop-powered signal conditioner
 RAIL-35-1    300.00 Kč   35 mm (1.4") DIN rail, 1 m (3.3') length
 DRSL-MOD-STOP    150.00 Kč   Module stop (screwed onto DIN rail to support and hold mounted devices)
Obsah košíku Vyprázdnit košík Objednat
 * využijte možnost konzultovat ceny pøímo s našimi prodejci  (tel: 596 311 899 - prodejní oddėlení, e-mail: viz. kontaktní informace)
 Pøíklad objednávky: (1) DRSL-MOD-STOP Module stop (screwed onto DIN rail to support and hold mounted devices), (1) DRSL-RTD-LP RTD input non-isolated DIN rail loop-powered signal conditioner, (1) RAIL-35-1 35 mm (1.4 = 3,000.00 Kč

 Literatura
   Stáhnout kompletní specifikace produktu ve formátu PDF
 Manuály
   Stáhnout  Installation Guide for Signal Conditioners
   Stáhnout  DIN Rail Isolators and Signal Conditioners
 Souvísející odkazy
   DRSL-DC1: Isolated DIN Rail Repeater
   DRSL-DC2: Isolated DIN Rail Signal Conditioner
   DRSL-DC3: Isolated DIN Rail Signal Conditioner
   DRSL-DC4: Bipolar Isolated DIN Rail Signal Conditioner for Process Signals
   DRSL-LPI_Series: DIN Rail Input Loop-Powered Isolators
   DRSL-LPO_Series: DIN Rail 2-Wire Transmitter Isolators
   DRSL-RTD_Series: RTD Input DIN Rail Signal Conditioners
   DRSL-SP1: Isolated DIN Rail Repeater/Splitter for Current Signals
   DRSL-SP2: Isolated DIN Rail Signal Conditioner/Splitter for Process Signals
   DRSL-SP3: Bipolar Isolated DIN Rail Signal Conditioner/Splitter for Process Signals
   DRSL-TC_Series: Thermocouple Input DIN Rail Signal Conditioners
   DRSL-TEMP: Isolated DIN Rail Loop-Powered Temperature Signal Conditioner
   DRSL-U: Isolated Universal Input DIN Rail Signal Conditioner