FD-400 Series
Ultrasonic Doppler Flowmeter

FD-400 Series : Ultrasonic Doppler Flowmeter
Kliknìte zde pro vìtší obrázek.

60,450.00  Kč *
     FD-400

  Non-Intrusive, Clamp-On Transducer for Most Pipes from 6 mm to 3m (1/4 to 120")
  Insertion Probe Transducer Also Available
  Wide Measuring Range of 0.05 to 9 mps (0.15 to 30 fps)
  ±2% of Calibrated Span Accuracy
  Configuration and Total Stored in Non-Volatile Flash ROM
  NEMA 4X (IP66) Outdoor Enclosure
  Provisions for Up to 4 Meters in a Single Piping System
  NIST Certificate

The FD-400 Series ultrasonic doppler flowmeters measure the flow of liquids that contain sound reflectors, suspended solids, or gas bubbles larger than 100 microns. These sophisticated instruments automatically adjust filtering and gain settings to produce reliable readings in a wide range of liquid and reflector conditions.

The FD-400 flowmeter transmitts ultrasonic sound through the pipe wall or from the probe tip into the flowing liquid by using piezoelectric crystals contained in the transducer and probe tip. The sound is then reflected by sonic reflectors suspended in the liquid and recorded by the receiver. If the sonic reflectors are moving within the sound transmission path, sound waves will be reflected at a frequency shifted (Doppler frequency) from the transmitted frequency. The difference between the 2 frequencies is directly proportional to the speed of the sonic reflectors, resulting in a liquid flow rate that is converted to various user-defined units.

Configuration of the FD-400 is accomplished via the front-panel keypad. A 2-line backlit LCD displays rate and total in user-selected units. Power supply options include AC and DC. Optional outputs include 4 to 20 mA, relays, and rate pulse.

Two transducer styles are available. The FD-400C clamp-on, non-intrusive transducer is recommended for most metal or plastic pipes. The FD-400C has a NEMA 6P (IP68) rating and is available in a high-temperature version, "=HT". The user can place these clamp-on transducers up to 305 m (1000') from the display enclosure. The FD-400I insertion probe transducer should be used on piping systems that do not permit ultrasonic penetration. The FD-400I inserts into the pipe wall and comes into direct contact with the flowing liquid.

SPECIFICATIONS
GENERAL

Measuring Principle: Doppler ultrasonic
Flow Velocity Range: 0.05 to 9 mps (0.15 to 30 fps)
Accuracy: ±2% FS over calibrated span
Liquid Types: Liquids containing 100 ppm of useful sonic-suspended reflectors greater than 100 microns

MONITOR
Enclosure: NEMA 4X (IP66), polycarbonate, stainless steel, brass, plated-steel mounting brackets
Dimensions: 178 H x 146 W x 99 mm D (7.00 x 5.75 x 3.88")
Power Supply: 115/230 Vac, 50/60 Hz ±15% @ 5 VA max; 12 to 28 Vdc @ 2.5 VA max
Display: 2-line x 8-character LCD; LED backlighting; top row, 7-segment 18 mm (0.7"); bottom row, 14-segment 9 mm (0.35"); 8-digit rate, 8-digit total (resettable)
Units: User configured—feet, gallons, ft3, mil-gal, meters, liters, mil ft3, m3, mil-liters, acre-feet, oil barrels (42 gallon), liquor barrels (32.5 gallons), lb, kg
Rate: Interval—second, minute, hour, day
Totalizer exponent: E-2 to E+6
Response Time: User selectable, 1 to 60 seconds
Outputs: 4 to 20 mA, 800 Ω max; internal or external power supply; 12-bit resolution; optically isolated
Dual Relay: Independently configured; form “C”, 200 Vac @ 0.5 A resistive; rate alarm, totalizer pulse, error
Rate Pulse: 2 output types— 500 mVac or open collector; 2500 Hz max; 12-bit resolution; 500 mV AC into 2 kΩ min; open collector 1 A at 100 V max
Multiple Meters: Synchronization provision included—used for multiple meter/single pipe system; up to 4 meters may be interconnected to 30 m (100') apart
Keypad: 4 pushbutton keys
Operating Temperature: General purpose, 40 to 85°C (40 to 185°F)

TRANSDUCERS
Type: Compression-mode ultrasonic, 625 kHz
Housing Material:
    Standard Clamp-On: NEMA 6P (IP68), -40 to 100°C (-40 to 210°F), CPVC, Ultem®, nylon, PVC (cable jacket), aluminum (small pipe)
    High-Temp Clamp-On: NEMA 4 (IP65), -40 to 200°C (-40 to 400°F), Vespel®, anodized aluminum, nickel-plated brass, PFA (cable jacket)
    Doppler Probe: NEMA 6 (IP67) -40 to 100°C (-40 to 210°F); 700 psi (48 bar) max, 316 SS, Ultem®, FKM, nylon, PVC (cable jacket)
    Optional Flexible Armored Conduit: Zinc-plated steel, PVC
Cable Length:
    Standard Lengths: 6 m (20') standard


 Èíslo modelu  Cena (bez DPH)  Popis  Ks
 FD-400    60,450.00 Kč   Ultrasonic rate and totalizer
 FD-400-24VDC    60,450.00 Kč   Ultrasonic rate and totalizer 12-28VDC input power
 FD-410    68,700.00 Kč   Rate and totalizer with 4 to 20 mA output
 FD-410-24VDC    68,700.00 Kč   Rate and totalizer with 4 to 20 mA output, 12-28 VDC input power
 FD-411    76,950.00 Kč   Rate and totalizer with two 4 to 20 mA outputs
 FD-412    76,950.00 Kč   Rate and totalizer with 4 to 20 mA and 2 relay outputs
 FD-413    76,950.00 Kč   Rate and totalizer with 4 to 20 mA and pulse outputs
 FD-420    68,700.00 Kč   Rate and totalizer with 2 relay outputs
 FD-422    76,950.00 Kč   Rate and totalizer with 4 relay outputs
 FD-423    76,950.00 Kč   Rate and totalizer with 2 relays and a pulse output
 FD-430    76,950.00 Kč   Rate and totalizer with pulse output
 FD-433    76,950.00 Kč   Rate and totalizer with 2 pulse outputs
 FD-400C-STD    32,400.00 Kč   Standard-size clamp-on transducer set, 25 to 3050 mm (1 to 120")
 FD-400C-STD-50FT    35,100.00 Kč   Standard-size clamp-on transducer set, 25 to 3050 mm (1 to 120") 15 m (50')
 FD-400C-STD-100FT    38,400.00 Kč   Standard-size clamp-on transducer set, 25 to 3050 mm (1 to 120") 30 m (100')
 FD-400C-SML    43,500.00 Kč   Small-pipe clamp-on transducer set, 6 to 25 mm (1.4 to 1")
 FD-400C-SML-50FT    46,050.00 Kč   Small-pipe clamp-on transducer set, 6 to 25 mm (1.4 to 1") 15 m (50')
 FD-400C-SML-100FT    49,350.00 Kč   Small-pipe clamp-on transducer set, 6 to 25 mm (1.4 to 1") 30 m (100')
 FD-400C-STD-HT    52,050.00 Kč   Standard-size clamp-on transducer set for high temperature, 25 to 3050 mm (1 to 120")
 FD-400C-STD-HT-50FT    54,600.00 Kč   Standard-size clamp-on transducer set for high temperature, 25 to 3050 mm (1 to 120") 15 m (50')
 FD-400C-STD-HT-100FT    58,050.00 Kč   Standard-size clamp-on transducer set for high temperature, 25 to 3050 mm (1 to 120") 30 m (100')
 FD-400C-SML-HT    59,100.00 Kč   Small-pipe clamp-on transducer set for high temperature, 6 to 25 mm (1.4 to 1")
 FD-400C-SML-HT-50FT    61,650.00 Kč   Small-pipe clamp-on transducer set for high temperature, 6 to 25 mm (1.4 to 1") 15 m (50')
 FD-400C-SML-HT-100FT    65,100.00 Kč   Small-pipe clamp-on transducer set for high temperature, 6 to 25 mm (1.4 to 1") 30 m (100')
 FD-400I-8    40,500.00 Kč   Insertion transducer sensor 8"
 FD-400I-18    50,400.00 Kč   Insertion transducer sensor 18"
 FD-400I-18-50 FT    53,400.00 Kč   Insertion Transducer sensor 18" with 50 feet of cable
 FD-400I-28    58,500.00 Kč   Insertion transducer sensor 28"
 FD-400I-38    67,200.00 Kč   Insertion transducer sensor 38"
 FD-400I-48    73,650.00 Kč   Insertion transducer sensor 48"
 FD-400I-CR-18    47,850.00 Kč   Insertion crank for FD-400I-18
 FD-400I-CR-28    55,650.00 Kč   Insertion crank for FD-400I-28
 FD-400I-CR-38    63,900.00 Kč   Insertion crank for FD-400I-38
 FD-400I-CR-48    70,050.00 Kč   Insertion crank for FD-400I-48
 FD-400I-BV    6,900.00 Kč   Bronze valve isolation kit 11.2 NPT
 FD-400I-SFK    3,210.00 Kč   Probe insertion fitting seal kit
 FD-400I-SSV    11,160.00 Kč   Stainless steel valve isolation kit 11. NPT
 FD-GREASE    490.00 Kč   Replacement acoustic couplant for sensor mounting, max temperature 65C (150F), 6 g (.2 oz) pillow pack
 FDT-GREASE    1,440.00 Kč   Acoustic couplant for sensor mounting, max temperature 65C (150F), 150g (5.3 oz) tube
 FDT-HT-GREASE    3,540.00 Kč   Acoustic couplant for sensor mounting, max temperature 200C (392F), 56.7g (2 oz) tube
 FDT-NS-GREASE    1,440.00 Kč   Non-silicone acoustic couplant for sensor mounting, 79 g (2.8 oz) tube
Obsah košíku Vyprázdnit košík Objednat
 * využijte možnost konzultovat ceny pøímo s našimi prodejci  (tel: 596 311 899 - prodejní oddìlení, e-mail: viz. kontaktní informace)
 Poznámka: Meters come complete with wall mount bracket, NIST Certificate, and operator's manual.

Clamp-on Transducer Sets come complete with acoustic couplant.

Rate indicator/totalizer models are also available with 24 Vdc or 230 Vac power: For 24 Vdc power, add suffix "-24VDC" to model number, no additional cost.
For 230 Vac power, add suffix "-230VAC" to model number, no additional cost.

FD-400C-STD sensors come with four mounting straps.

FD-400C-SML sensors do not come with mounting straps.

Armored cable and longer lengths available; consult Omega Flow Engineering.

For insertion-style transducers with 15 m (50') of cable, add suffix "-50FT" to model number, add $95 to the price.

For insertion-style transducers with 30 m (100') of cable, add suffix "-100FT" to model number, add $221 to price.


 Pøíklad objednávky: (1) FD-400 Ultrasonic rate and totalizer, (1) FD-400C-STD Standard-size clamp-on transducer set, 25 to 3050 mm (1 to 120 = 92,850.00 Kč

 Literatura
   Stáhnout kompletní specifikace produktu ve formátu PDF
 Manuály
   Stáhnout  FD-400 Series - Doppler Ultrasonic Flow Meter