FD613 and FD614
Portable Doppler Ultrasonic Flow meters

FD613 and FD614 : Portable Doppler Ultrasonic Flow meters
Kliknìte zde pro vìtší obrázek.
  100 PPM OF 100 Microns in Size Paticulate or Bubbles Required
  Battery Operated
  Non-Invasive Clamp-On Transducer
  Large Character Display
  User Selected Velocity Units (FPS or MPS)
  Measures Fluid Velocities from 0.3 to 30.0 FPS (0.10 to 9.00 MPS)
  100:1 Turndown Ratio
  Pipe Sizes from 6.3 mm (0.25")
  CE Version Available
  NIST Standard

The FD613 Series ultrasonic flow meter features advanced Trans-Phase measuring technology, providing accurate and reliable flow velocity assessments in closed full pipe systems. The FD613 utilizes a non- invasive clamp-on transducer which is placed on the outside of a pipe. Within seconds, the large 18 mm (0.7") LCD provides stable flowrate readings in feet (or meters) per second. This product operates on metal or plastic pipes containing liquids with more than 100 ppm of 100 micron or larger suspended solids or entrained gases.

PRINCIPLE OF OPERATION
The FD613 Series flowmeter utilizes an advanced Trans-Phase measuring technique, providing accurate, non-invasive fluid velocity assessment without opening the pipe. The FD613 Series utilizes two piezoelectric crystals contained within one transducer to transmit ultrasonic energy into the fluid stream and receive back energy reflected off discontinuities (suspended particles or entrained gases) within the moving liquid. Transformations that result from the energy reflections are processed and converted to a measurement of fluid velocity by the sophisticated software algorithm. The processor also controls all operations of the instrument from its ultra-efficient battery management circuitry to a proprietary FIR (Finite Impulse Response) filtration program.

SPECIFICATIONS
Supply Voltage: Battery powered, non-rechargeable alkaline, four AA cells, providing over 30 hours of continuous operation
Flow Range: 0.30 to 30.00 FPS (0.10 to 9.00 MPS)
Display: Single line – four-digit LCD readout of velocity (18 mm (0.7") digits), signal strength, measuring units, and low battery indication
Temperature: -20 to 60°C (-28 to 140°F)
Enclosure Rating/Dimensions: NEMA-12X ABS plastic; 200 H x 100 W x 38 mm H (7.76 x 4 x 1.5")
Weight: 0.7 kg (1.5 lb)
Accuracy: ±2% full scale
Transducer
Transducer Material: Plated body; ULTEM 1000 sensor material
Cable: 2 m (6.6 ft) cable and connector
Temperature: -40 to 82°C (-40 to 180°F)
Humidity: 0 to 95% non-condensing
Mounting Method: Clamp-on style with DOW 111 coupling compound


 Èíslo modelu  Cena (bez DPH)  Popis  Ks
 FD613    51,450.00 Kč   Handheld readout, carrying case, Silicone Couplant, and 4 AA batteries; sensor sold separately
 FD613-S1    20,100.00 Kč   Clamp-on sensor for 1/4 to 1" diameter pipe; for FD613 only (small pipe sensor has a two-piece clamp on head)
 FD613-S2    16,650.00 Kč   Clamp-on sensor for pipes 1" dia. and larger; for FD613 only
 FD614-CE    76,200.00 Kč   FD613 kit with CE approval and sensor; for pipes 1" dia. and larger
 FD614-S2-CE    41,400.00 Kč   Replacement sensor for pipes 1" and larger with CE approval for use with FD614-CE
 FD-GREASE    490.00 Kč   Replacement acoustic couplant for sensor mounting, max temperature 65°C (150°F), 6 g (0.2 oz) pillow pack
 FDT-GREASE    1,440.00 Kč   Replacement acoustic couplant for sensor mounting, max temperature 65°C (150°F), 150 g (5.3 oz) tube
 FDT-HT-GREASE    3,540.00 Kč   Acoustic couplant for sensor mounting, max temperature 200°C (392°F), 56.7g (2 oz) tube
 FDT-NS-GREASE    1,440.00 Kč   Non-silicone acoustic couplant for sensor mounting, 79 g (2.8 oz) tube
 MN1500-4    80.00 Kč   Replacement Alkaline "AA" batteries (qty 4)
Obsah košíku Vyprázdnit košík Objednat
 * využijte možnost konzultovat ceny pøímo s našimi prodejci  (tel: 596 311 899 - prodejní oddìlení, e-mail: viz. kontaktní informace)
 Poznámka: FD613 comes complete with carrying case, silicone couplant, 4 "AA" batteries, NIST cetificate and operator's manual.

FD613 sensors sold separately.

FD614-CE comes with carrying case, silicone couplant, 4 "AA" batteries, 1 FD614-S2-CE clamp on sensor for pipes 1" diameter and larger, NIST certificate and operator's manual.

FD614-CE comes complete with sensor. If replacement or spare sensor is required order FD614-S2-CE.

FD614-CE and FD613 sensors are not interchangeable.


 Pøíklad objednávky: (1) FD613 Handheld Ultrasonic Readout, (1) FD613-S1 Clamp-on sensor for 1 / 4 = 71,550.00 Kč