FMA6600 and FMA6700 Series
Multi Parameter Mass Flowmeter

FMA6600 and FMA6700 Series : Multi Parameter Mass Flowmeter
Kliknìte zde pro vìtší obrázek.

45,150.00  Kč *
     FMA6701

  Multi-Drop Capability of Up to 256 Units (for RS-485 Option)
  Stores Calibration Data for Up to 10 Different Gases
  Supports 10 Different Engineering Units Including User Defined
  Programmable 12 Digits Totalizer Indicates Total Gas Volume
  Flow Alarm Limits for High and Low Gas Flow with Relay Output
  Pressure Alarm (FMA6700) Limits for High and Low Gas Pressure with Relay Output
  Temperature Alarm (FMA6700) Limits for High and Low Gas Temperature with Relay Output
  Digital (RS-232 or RS-485) and Analog Outputs Operate Simultaneously
  Internal Conversion Factors for Up to 32 Gases

Interface
All features of the FMA6600 and FMA6700 Series flow meters can be accessed via the local four button keypad and LCD. The digital interface operates via RS485 (optional RS-232 available) and provides access to applicable internal data including: flow, temperature, pressure reading, auto zero, totalizer and alarms settings, gas table, conversion factors and engineering units selection, dynamic response compensation and linearization table adjustment. The analog interface provides 0 to 5 Vdc or 0 to 10 Vdc or 4 to 20 mA outputs for flow, pressure and temperature (jumper selectable).
Auto Zero
The FMA6600 and FMA6700 Series supports automatic sensor zero offset adjustment that can be activated locally via keypad or remotely via digital interface. The auto zero feature requires absolutely no flow through the meter during auto zero process. Provisions are made to either start, stop or save the current auto zero value via digital commands.
Totalizer
The total volume of the gas is calculated by integrating the actual gas flow rate with respect to time. Both keypad menu and digital interface commands are provided to: • set the totalizer to ZERO • start the totalizer at a preset flow • assign action at a preset total volume • start/stop totalizing the flow • read totalizer Totalizer conditions become true, when the totalizer reading and the "Stop at Total" volumes are equal.
Flow Alarm
High and Low gas flow ALARM limits can be preprogrammed via keypad or remotely via digital interface. ALARM conditions become true when the current flow reading is equal or higher/lower than corresponding values of high and low alarm levels. Alarm action can be assigned with preset delay interval (0-3600 seconds) to activate the contact closer (separate for High and Low alarm). Pressure Alarm (FMA6700 Series) High and Low gas pressure ALARM limits can be preprogrammed via keypad or remotely via digital interface. Pressure alarm conditions become true when the current pressure reading is equal or higher than corresponding values of high pressure alarm settings or equal or lower than corresponding values of low pressure alarm settings. Alarm action can be assigned to activate the contact closer (separate for High and Low pressure alarm). Temperature Alarm (FMA6700 Series) High and Low gas temperature ALARM limits can be preprogrammed via keypad or remotely via digital interface. Temperature alarm conditions become true when the current temperature reading is equal or higher than corresponding values of high temperature alarm settings or equal or lower than corresponding values of low temperature alarm settings. Alarm action can be assigned to activate the contact closer (separate for High and Low temperature alarm).
Engineering Units
The flow set points, measured gas flow and associated totalizer data are scaled directly in engineering units via the front panel keypad or digital interface. The following units of measure are supported: %F.S., L/min, L/h, mL/min, mL/h, SCFH, SCFM, LbPH, LbPM, User Defined EU.
Multi-Gas Calibration
The FMA6600 Series is capable of storing primary calibration data for up to 10 gases. This feature allows the same FMA6600 Series to be calibrated for multiple gases while maintaining the rated accuracy on each.
Standard 10-Point NIST Calibration
Optional up to 9 additional 10-point calibration may be ordered at an additional charge per gas.
Conversion Factors
Conversion factors for up to 32 gases are stored in the FMA6600 and FMA 6700 Series. In addition, the provision is made for a user defined conversion factor. Conversion factors may be applied to any of the ten gas calibrations via keypad or digital interface commands.
Contact Closure
Two sets of dry contact relay outputs are provided to actuate user supplied equipment. These are programmable via local keypad or digital interface such that the relays can be made to switch when a specified event occurs (e.g. when a low or high flow, pressure or temperature alarm limit is exceeded or when the totalizer reaches a specified value).
Leak Integrity
1 x 10-9 sccs of Helium maximum to the outside environment.

FMA6600/FMA6700 Transducers should not be used for monitoring Oxygen gas unless specifically cleaned and prepared for such application. See below for ordering details.

SPECIFICATIONS
Accuracy:
   FMA6700: ±1% of FS including linearity [0 to 50°C and 0.35 to 6.8 bar (5 to 100 psia)]
   FMA6600: ±1% of FS at calibration conditions [101 KPa (14.7 psia) and 21.1°C (70°F)]
Pressure Range: 0 to 6.8 bar (100 psig) (measurement)
Pressure Accuracy: ±1% of FS
Temperature Range: 0 to 50°C (measurement)
Temperature Accuracy: ±1°C
Repeatability: ±0.15% of full scale
Response Time: Units up to 10 LPM @1.0 second, units greater than 10 LPM @2 seconds to within ±2% of setpoint over 25% to 100% of full scale
Temp. Coefficient: 0.15% of full scale/°C or better
Pressure Coefficient: 0.01% of full scale/psi (0.07 bar) or better
Max Gas Pressure: 6.8 bar (100 psig)
Max Burst Pressure: 13.6 bar (200 psig)
Max Pressure Drop: 8 psi (at 100 L/min flow)
Gas & Ambient Temp: 5 to 50°C (41 to 122°F)
Output Signals: Linear 0 to 5 Vdc (3000 Ω min load impedance); 0 to 10 Vdc (6000 Ω min impedance); 4 to 20 mA optional (500 . max loop resistance). Maximum noise 20 mV peak to peak.
Input Power: Is available to run at three different voltages: ±15Vdc (±200 mA maximum) or +12Vdc (300 mA maximum) standard; +24Vdc (250 mA maximum) optional (-24VDC); Circuit boards have built-in polarity reversal protection. Resettable fuses provide power input protection.
Materials in Fluid Contact: 316 stainless steel, FKM O-rings. EPDM or Perfluoroelastomer O-rings optional
Connections:
   Models ≥15 LPM: Standard 1/4" compression fittings
   Models 20 to 50 LPM: Standard 1/4" compression fittings
   Models 60 to 100 LPM: Standard 3/8" compression fittings
Display: 128 x 64 graphic LCD with backlight (up to 8 lines of text)
Calibration: Standard one 10 points NIST calibration. Optional up to 9 additional calibrations may be ordered for an additional charge per gas.
CE Compliance: EN 55011 class 1, class B; EN50082-1
Environmental (per IEC 664): Installation Level II; Pollution Degree II
Approximate Shipping Weights:
   Models up to 15 SLPM: 1.68 kg (3.7 lb)
   Models from 20 to 100 LPM: 1.97 kg (4.34 lb)


 Èíslo modelu  Cena (bez DPH)  Popis  Ks
 FMA6601    36,600.00 Kč   Max Flow 10 cc/min 1/4' Compression Fitting
 FMA6602    36,600.00 Kč   Max Flow 20 cc/min 1/4' Compression Fitting
 FMA6603    36,600.00 Kč   Max Flow 50 cc/min 1/4' Compression Fitting
 FMA6604    36,600.00 Kč   Max Flow 100 cc/min 1/4' Compression Fitting
 FMA6605    36,600.00 Kč   Max Flow 200 cc/min 1/4' Compression Fitting
 FMA6606    36,600.00 Kč   Max Flow 500 cc/min 1/4' Compression Fitting
 FMA6607    36,600.00 Kč   Max Flow 1 LPM 1/4' Compression Fitting
 FMA6608    36,600.00 Kč   Max Flow 2 LPM 1/4' Compression Fitting
 FMA6609    36,600.00 Kč   Max Flow 5 LPM 1/4' Compression Fitting
 FMA6610    36,600.00 Kč   Max Flow 10 LPM 1/4' Compression Fitting
 FMA6611    39,600.00 Kč   Max Flow 15 LPM 1/4' Compression Fitting
 FMA6612    39,600.00 Kč   Max Flow 20 LPM 1/4' Compression Fitting
 FMA6613    39,600.00 Kč   Max Flow 30 LPM 1/4' Compression Fitting
 FMA6614    39,600.00 Kč   Max Flow 40 LPM 1/4' Compression Fitting
 FMA6615    39,600.00 Kč   Max Flow 50 LPM 1/4' Compression Fitting
 FMA6616    42,750.00 Kč   Max Flow 60 LPM 3/8' Compression Fitting
 FMA6617    42,750.00 Kč   Max Flow 80 LPM 3/8' Compression Fitting
 FMA6618    42,750.00 Kč   Max Flow 100 LPM 3/8' Compression Fitting
 FMA6701    45,150.00 Kč   Max Flow 10 cc/min 1/4' Compression Fitting
 FMA6702    45,150.00 Kč   Max Flow 20 cc/min 1/4' Compression Fitting
 FMA6703    45,150.00 Kč   Max Flow 50 cc/min 1/4' Compression Fitting
 FMA6704    45,150.00 Kč   Max Flow 100 cc/min 1/4' Compression Fitting
 FMA6705    45,150.00 Kč   Max Flow 200 cc/min 1/4' Compression Fitting
 FMA6706    45,150.00 Kč   Max Flow 500 cc/min 1/4' Compression Fitting
 FMA6707    45,150.00 Kč   Max Flow 1 LPM 1/4' Compression Fitting
 FMA6708    45,150.00 Kč   Max Flow 2 LPM 1/4' Compression Fitting
 FMA6709    45,150.00 Kč   Max Flow 5 LPM 1/4' Compression Fitting
 FMA6710    45,150.00 Kč   Max Flow 10 LPM 1/4' Compression Fitting
 FMA6711    48,000.00 Kč   Max Flow 15 LPM 1/4' Compression Fitting
 FMA6712    48,000.00 Kč   Max Flow 20 LPM 1/4' Compression Fitting
 FMA6713    48,000.00 Kč   Max Flow 30 LPM 1/4' Compression Fitting
 FMA6714    48,000.00 Kč   Max Flow 40 LPM 1/4' Compression Fitting
 FMA6715    48,000.00 Kč   Max Flow 50 LPM 1/4' Compression Fitting
 FMA6716    51,150.00 Kč   Max Flow 60 LPM 3/8' Compression Fitting
 FMA6717    51,150.00 Kč   Max Flow 80 LPM 3/8' Compression Fitting
 FMA6718    51,150.00 Kč   Max Flow 100 LPM 3/8' Compression Fitting
 FMA66-PW    6,570.00 Kč   115 Vac to ±15 Vdc power supply
 FMA66-12PW    1,830.00 Kč   115 Vac to 12 Vdc power supply
 FMA66-24PW    1,830.00 Kč   115 Vac to 24 Vdc power supply
 FMA66-230EU    6,570.00 Kč   239 Vac to ±15 Vdc power supply
 FMA66-12PW-230EU    2,130.00 Kč   230 Vac to 12 Vdc power supply
 FMA66-24PW-230EU    2,130.00 Kč   230 Vac to 24 Vdc power supply
 FMA65-C    1,740.00 Kč   Replacement cable, 25-pin D connector with 1.8 m (6') wire branch to power supply
Obsah košíku Vyprázdnit košík Objednat
 * využijte možnost konzultovat ceny pøímo s našimi prodejci  (tel: 596 311 899 - prodejní oddìlení, e-mail: viz. kontaktní informace)
 Poznámka: Comes complete with operator’s manual and NIST traceable certificate for Nitrogen.
Power supply sold separately.

Note: Flow rates are stated for Nitrogen at STP conditions (21.1°C (70°F) at 1 atm).

For 12Vdc power, add suffix "-12VDC" to model number; add $100 to price.

For 24Vdc power, add suffix "-24VDC" to model number; add $200 to price.

For perfloroelastomer, Buna or EPR o-rings, VCR fittings, or RS232 communications, consult Flow Engineering for a quote.

For each additional calibration add -(*) to the part number and $300.00 to the cost.

Calibrations done at ambient temperature only.

For Oxygen cleaned units, add suffix "-C" to the model number; add $125 to price.

(OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)


 Pøíklad objednávky: (1) FMA66-PW Power Supply, (1) FMA6609 1/4'' compression fitting, 5 LPM max. = 43,170.00 Kč

(1) (2) (3)
FMA
Popis voleb
(1) Model Type
  Vyberte 66 pro Flowmeter, 67 pro Flow/Pressure/Temperature meter
(2) Range (N2)
  Vyberte 01 pro 10 SCCM, 02 pro 20 SCCM, 03 pro 50 SCCM, 04 pro 100 SCCM, 05 pro 200 SCCM, 06 pro 500 SCCM, 07 pro 1 SLM, 08 pro 2 SLM, 09 pro 5 SLM, 10 pro 10 SLM, 11 pro 15 SLM, 12 pro 20 SLM, 13 pro 30 SLM, 14 pro 40 SLM, 15 pro 50 SLM, 16 pro 60 SLM, 17 pro 80 SLM, 18 pro 100 SLM
(3) Options
  Vyberte prázdné pole pro no options (standard unit), -I pro 4 to 20 mA output (replaces std 0 to 5 V), -12V pro 12 Vdc power, -24V pro 24 Vdc power, -K pro Perfluoroelastomer o-rings, -B pro Buna o-rings, -E pro EPR o-rings, -VCR pro VCR fittings, -RS232 pro RS232 communications (replaces std RS485)
 Poznámka: ne všechny kombinace jsou správné, ovìøte si správnost èísla modelu.

 Literatura
   Stáhnout kompletní specifikace produktu ve formátu PDF
 Manuály
   Stáhnout  FMA6600 and FMA6700 Series - Multi Parameter Digital Mass Flow Meters