FTB-100 Series
Turbine Flowmeters with Economical Ball Bearing Design

FTB-100 Series : Turbine Flowmeters with Economical Ball Bearing Design
Kliknìte zde pro vìtší obrázek.
  NIST Certificate Included for Water
  ±1/2% Rdg Accuracy
  Non-Metallic Bearing Retainers for Long Life
  Replacement Bearings Field Installable Without Loss of Calibration
  Disassembles Quickly for Easy Maintenance
  Deflector Cones Stabilize Low Mass Rotor for Increased Bearing Life
  4 to 20 mA, 0-5 V, and Scaled Frequency Outputs Available

The FTB-100 Series of turbine meters have a sealed ball bearing design for high accuracy performance (±½% of reading, not full scale) at an economical cost. The non-metallic bearing retainers minimize friction, thereby allowing these meters to be used with clean fluids that have poor lubricating properties ( i.e.water). Ball bearings also give the widest linear flow range, particularly in larger turbines. Bearing replacement and clean-up are fast and easy, since all internal parts are easily accessible by removing a single nut.

These turbine flowmeters have a low mass rotor design which allows rapid dynamic response, so they can be used in pulsating flow applications. Deflector cones eliminate downstream thrust on the rotor and allow hydrodynamic positioning of the rotor between the cones. This provides wider rangeability and longer bearing life than conventional turbine flowmeters. Integral flow-straightening tubes minimize the effects of upstream turbulence.
FTB-100 Turbine Meters are available with integral signal conditioners (as shown in photo) which provide scaled and unscaled frequencies, 4-20 mA, or 0-5 Volt outputs. Units without integral signal conditioners are supplied with mating connector for two-wire hook-up.

SPECIFICATIONS
Accuracy: ±½% of reading
Repeatability: ±0.1% of reading
Maximum Temperature Range: -268 to 232°C (-450 to 450°F)
Maximum Intermittent Overrange: 150% of maximum range
Minimum Output Amplitude: 30 mV Peak-to-Peak Unscaled Pulse
Materials of Construction:
   Body: 304 stainless steel; 1/2 NPT bodies contain Silver Solder. 3/4 NPT and larger are welded.
   Rotor: 17-4 pH steel
   Bearings: Ceramic
Minimum straight pipe requirements: 10 pipe diameters upstream, 5 downstream

Model No. Fittings Linear Flow Range
Water
Max Operating Pressure Max Pressure Drop Length
mm (in)
Nominal
K-Factor
Pulses/Gal
Weight
kg (lb)
LPM GPM
FTB-101 ½ MNPT 1.32 to 13.2 0.35 to 3.5 5000 psig 3.0 psid 62 (2.45) 13,000 0.4 (1)
FTB-102 ½ MNPT 2.84 to 28.4 0.75 to 7.5 5000 psig 5.0 psid 62 (2.45) 10,000 0.4 (1)
FTB-103 ½ MNPT 4.73 to 36 1.25 to 9.5 5000 psig 5.2 psid 62 (2.45) 6,000 0.4 (1)
FTB-104 ¾ MNPT 6.62 to 61 1.75 to 16 5000 psig 3.0 psid 70 (2.75) 4,100 0.4 (1)
FTB-105 ¾ MNPT 9.5 to 110 2.5 to 29 4250 psig 5.0 psid 83 (3.25) 2,200 0.4 (1)
FTB-106 1 MNPT 15 to 227 4 to 60 3850 psig 5.1 psid 89 (3.5) 640 0.9 (2)
FTB-107 1¼ MNPT 23 to 352 6 to 93 3850 psig 4.3 psid 99 (3.88) 410 0.9 (2)
FTB-108 1½ MNPT 30 to 492 8 to 130 3000 psig 3.0 psid 111 (4.38) 230 1.4 (3)
FTB-109 2 MNPT 57 to 852 15 to 225 2500 psig 3.3 psid 121 (4.75) 120 1.8 (4)
FTB-110 2½ MNPT 95 to 1514 25 to 400 2250 psig 4.0 psid 154 (6.06) 62 2.3 (5)
FTB-111 3 MNPT 151 to 2460 40 to 650 2000 psig 4.0 psid 191 (7.50) 55 3.2 (7)


 Èíslo modelu  Cena (bez DPH)  Popis  Ks
 FTB-101    35,370.00 Kč   0.35-3.5 GPM Range, Water; 1/2 MNPT
 FTB-102    35,370.00 Kč   0.75-7.5 GPM Range, Water; 1/2 MNPT
 FTB-103    35,370.00 Kč   1.25-9.5 GPM Range, Water; 1/2 MNPT
 FTB-104    35,370.00 Kč   1.75-16 GPM Range, Water; 3/4 MNPT
 FTB-105    35,370.00 Kč   2.5-29 GPM Range, Water; 3/4 MNPT
 FTB-106    39,120.00 Kč   4-60 GPM Range, Water; 1 MNPT
 FTB-107    41,640.00 Kč   6-93 GPM Range, Water; 1¼ MNPT
 FTB-108    42,750.00 Kč   8-130 GPM Range, Water; 1½ MNPT
 FTB-109    50,400.00 Kč   15-225 GPM Range, Water; 2 MNPT
 FTB-110    65,070.00 Kč   25-400 GPM Range, Water; 2½ MNPT
 FTB-111    65,070.00 Kč   40-650 GPM Range, Water; 3 MNPT
Obsah košíku Vyprázdnit košík Objednat
 * využijte možnost konzultovat ceny pøímo s našimi prodejci  (tel: 596 311 899 - prodejní oddìlení, e-mail: viz. kontaktní informace)
 Poznámka: Comes with NIST certificate for water and complete operator’s manual.
Standard NIST calibration: Viscosity = 1CK: no charge; 0.8 CK to 0.99 CK: add $369; 2 CK to 100 CK: for FTB-101 through FTB-107, add $369; for FTB-108 and FTB-109, add $356, and for FTB-110 and FTB-111, add $465.
If an integral signal conditioner is required please order as a system. Omega will scale the signal conditioner to the turbine meter.
Example: SYS/FTB-101/FLSC-C1-LIQ, scaled system includes: Signal Conditioner, Enclosure, Turbine Meter and Fitting, $1954.
(OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)
 Pøíklad objednávky: (1) FTB-105 Liquid turbine meter calibrated to water 2.5 to 29 GPM, .75 = 35,370.00 Kč

 Literatura
   Stáhnout kompletní specifikace produktu ve formátu PDF
 Manuály
   Stáhnout  FTB100 & FTB200 Series - Turbine Meters
 Souvísející odkazy
   DPF700 Series: 1/8 DIN 6-Digit Rate Meter/Totalizer
   DPF70 Series: Frequency Input Ratemeter/Totalizer
   FTB890 Series: PVDF Turbine Meter
   FLSC-C1-LIQ Series: integral or remote signal conditioner
   FLSC-C3-LIQ Series: integral or remote signal conditioner
   CL535: Frequency Calibrator with Totalizer