PHE-6300, PHE-5300, PHE-2114 and PHE-1304
Preamplified Alpha® Electrodes

PHE-6300, PHE-5300, PHE-2114 and PHE-1304 : Preamplified Alpha® Electrodes
Kliknìte zde pro vìtší obrázek.

3,090.00  Kč *
     PHE-1304-EB

  Interfaces Directly with Most Instrumentation that Accepts mV Input Signal
  Signal can be Run Up to 305 m (1000')
  Power Supply Available in Three Styles

OMEGA Engineering offers pH electrodes with integral preamplifiers for laboratory or industrial applications. These electrodes can interface directly with equipment that accepts a millivolt input signal with a 10 k1 or greater input impedance, such as a data acquisition interface or multimeter. The preamplifier converts the high impedance millivolt signal of the electrode into a low impedance signal, enabling the signal to be run up to 305 m (1000') without signal loss. The electrode is supplied with 1 to 3 m (3 to 10') of coaxial cable, depending on the model. If longer cable lengths are required, simply splice on extension cable.

These preamplified electrodes are available in a variety of styles and can interface with any pH meter, controller, transmitter, multimeter or data acquisition system with a one-to-one unity gain.

The preamplified power option comes in styles: an encapsulated battery design, suffix "-PB", an external battery style, suffix "-EB", and a style for use with an external dc power source, "-NB".
To order a preamplified electrode see the To Order guide below.

Model No. Description
PHE-1304-(*)Combination gel-filled, epoxy-bodied, general purpose laboratory
pH electrode. pH range 0 to 12, temp. 0 to 80°C (32 to 176°F).
PHE-2114-(*)Combination general purpose, large bulb, refillable glass pH
electrode. pH range 0 to 13, temp. 0 to 100°C (32 to 212).
PHE-5311-10-(*)Industrial in-line combination, general purpose, gel filled, pH
electrode, Kynar housing, 1/2" MNPT threading, insertion length 1".
10' of cable standard. pH range 0 to 13, temp. range
-5 to 100°C. (23 to 212°F). Dimensions: 127 x 25 mm (5 x 1").
PHE-5411-10-(*)Industrial in-line combination double junction electrode. MNPT
threading, insertion length 1". 10' of cable standard. pH range 0 to
13, temp. range -5 to 100°C (23 to 212°F).
Dimensions: 127 x 25 mm (5 x 1").
PHE-5316-10-(*)Industrial in-line combination, general purpose, gel-filled, pH
electrode, CPCV housing, 3/4" MNPT threading, 2" insertion length.
10' cable standard. pH range 0 to 13, temp. range
-5 to 80°C (23 to 176°F). Dimensions: 168 x 25 mm (6.6 x 1").
PHE-6351-10-(*)Industrial submersible, combination, general purpose,
gel-filled, pH electrode. Electrode potted in 36" ABS pipe.
10' cable standard. pH range 0 to 13, temp. range 0 to 80°C
(32 to 176°F). Dimensions: 28 x 914 mm (1.1 x 36").
PHE-6451-10-(*)Industrial submersible, combination, double junction,
gel-filled, pH electrode. Electrode potted in 36" ABS pipe.
10' cable standard. pH range 0 to 13, temp. range
0 to 80°C (32 to 176°F). Dimensions: 28 x 914 mm (1.1 x 36").


 Èíslo modelu  Cena (bez DPH)  Popis  Ks
 PHE-1304    1,170.00 Kč   Combination gel-filled, epoxy-bodied, general purpose laboratory pH electrode. pH range 0 to 12 temp. 0 to 80°C (32 to 176°F)
 PHE-1304-EB    3,090.00 Kč   Pre-amp electrode with replaceable external battery pack
 PHE-1304-NB    2,730.00 Kč   Pre-amp electrode, requires external DC power supply
 PHE-2114    2,790.00 Kč   Combination, general purpose, large bulb, refillable glass pH electrode. pH range 0 to 13, temp. 0 to 100°C (32 to 212°F)
 PHE-2114-EB    4,500.00 Kč   Pre-amp electrode with replaceable external battery pack
 PHE-2114-NB    4,260.00 Kč   Pre-amp electrode, requires external DC power supply
 PHE-2114-PB    4,590.00 Kč   Pre-amp electrode with battery encapsulated in the cap. Battery can not be replaced.
 PHE-5311-10    3,690.00 Kč   Industrial in-line combination, general purpose, gel-filled, pH electrode, PVDF housing, 1/2 MNPT threading, insertion length 1". pH range 0 to 13, temperature range -5 to 100°C (23 to 212°F)
 PHE-5311-10-EB    5,580.00 Kč   Pre-amp electrode with replaceable external battery pack
 PHE-5311-10-NB    5,190.00 Kč   Pre-amp electrode, requires external DC power supply
 PHE-5311-10-PB    5,580.00 Kč   Pre-amp electrode with battery encapsulated in the cap. Battery can not be replaced.
 PHE-5311-10-PT100    5,190.00 Kč   Industrial in-line combination, general purpose, gel filled, pH electrode with 100Ω Platinum RTD
 PHE-5311-10-PT1K    5,190.00 Kč   Industrial in-line combination, general purpose, gel filled, pH electrode with 1000Ω Platinum RTD
 PHE-5411-10    4,470.00 Kč   Industrial in-line combination double junction electrode, MNPT threading, insertion length 1". pH range 0 to 13, temperature range -5 to 100°C (23 - 212°F)
 PHE-5411-10-EB    6,420.00 Kč   Pre-amp electrode with replaceable external battery pack
 PHE-5411-10-NB    5,940.00 Kč   Pre-amp electrode, requires external DC power supply
 PHE-5411-10-PT100   Kontaktujte prodejce  Industrial in-line combination double junction electrode with 100Ω Platinum RTD
 PHE-5411-10-PT1K    5,940.00 Kč   Industrial in-line combination double junction electrode with 1000Ω Platinum RTD
 PHE-5316-10    3,330.00 Kč   Industrial in-line combination, general purpose, gel-filled pH electrode, CPCV housing, 3/4 MNPT threading, 2" insertionlength. pH range 0 to 13, temperature range -5 to 80°C (23 to 176°F)
 PHE-5316-10-PT100    4,830.00 Kč   Industrial in-line combination, general purpose, electrode with 100 Ω Platinum RTD
 PHE-5316-10-PT1K    4,830.00 Kč   Industrial in-line combination, general purpose, electrode with 1000Ω Platinum RTD
 PHE-6351-10    4,110.00 Kč   Industrial subersible, combination, general purpose gel-filled, pH electrode. pH range 0 to 13, temperature range 0 to 80°C (32 to 176°F)
 PHE-6351-10-EB    5,940.00 Kč   Pre-amp electrode with replaceable external battery pack
 PHE-6351-10-NB    5,580.00 Kč   Pre-amp electrode, requires external DC power supply
 PHE-6351-10-PB    5,760.00 Kč   Pre-amp electrode with battery encapsulated in the cap. Battery can not be replaced.
 PHE-6351-10-PT100    5,580.00 Kč   Industrial submersible, combination, general purpose gel-filled, pH electrode with 100Ω Platinum RTD
 PHE-6351-10-PT1K    5,580.00 Kč   Industrial submersible, combination, general purpose gel-filled, pH electrode with 1000Ω Platinum RTD
 PHE-6451-10    4,800.00 Kč   Industrial submersible, combination, double junction, gel-filled, pH electrode. pH range 0 to 13, temperature range 0 to 80°C (32 to 176°F)
 EB-SPARE    340.00 Kč   Spare battery pack for -EB option.
 PHE-DPS    1,560.00 Kč   ±3 Vdc power supply to operate preamplified electrodes, input 115 Vac
 PHA-10    360.00 Kč   pH 10 buffer solution, 500 ml (1 pt)
 PHA-10-GAL    900.00 Kč   pH 10 buffer solution, 4L (1 gal)
 PHA-4    360.00 Kč   pH 4 buffer solution, 500 ml (1 pt)
 PHA-4-GAL    900.00 Kč   pH 4 buffer solution, 4L (1 gal)
 PHA-7    360.00 Kč   pH 7 buffer solution, 500 ml (1 pt)
 PHA-7-GAL    900.00 Kč   pH 7 buffer solution, 4L (1 gal)
 PHA-DI    360.00 Kč   De-ionized water, 500 ml (1 pt)
 PHA-DI-GAL    900.00 Kč   De-ionized water, 4L (1 gal)
 PHAB-DI    920.00 Kč   20 single use foil packets of de-ionized water
 PHAB-PH    920.00 Kč   5 each single use foil packets of pH-4, pH-7, pH-10, and de-ionized water
Obsah košíku Vyprázdnit košík Objednat
 * využijte možnost konzultovat ceny pøímo s našimi prodejci  (tel: 596 311 899 - prodejní oddìlení, e-mail: viz. kontaktní informace)
 Poznámka: Comes complete with 1 to 3m (3 to 10') of cable and electrode care instruction sheet.

For non-standard cable lengths, replace te suffix "-10" with the desired length in feet; add $2 per foot. (Additional cost of $2 per foot applies to the entire cable length).


 Pøíklad objednávky: (1) PHE-5411-10-EB industrial in-line double junction preamplified electrode with external battery = 6,420.00 Kč

(1) (2)
PHE-
Popis voleb
(1) Code in Part Number
  Vyberte 1304 pro code 1304, 2114 pro code 2114, 5311-10 pro code 5311-10, 5316-10 pro code 5316-10, 6351-10 pro code 6351-10, 6451-10 pro code 6451-10
(2) Code in Part Number
  Vyberte prázdné pole, -EB pro Replaceable external battery pack, -PB pro Battery encapsulated in the cap of the electrode. Battery life approximately one year. Battery cannot be replaced, -NB pro Requires external dc power supply of ±1.5 Vdc to ±9 Vdc
 Poznámka: ne všechny kombinace jsou správné, ovìøte si správnost èísla modelu.

 Literatura
   Stáhnout kompletní specifikace produktu ve formátu PDF
 Souvísející odkazy
   PHA-4, PHA-7 and PHA-10: Pre-mixed pH Calibration Solutions