Economical Ball Bearing Turbine Flowmeters With 37 Degree Flare Fittings

FTB-200

Economical Ball Bearing Turbine Flowmeters With 37 Degree Flare Fittings | FTB-200

Prohlédněte si všechny modely

RoHS
  • ±½% of Reading Accuracy
  • Ball Bearing Design for Economy
  • Deflector Cones Stabilize Low Mass Rotor for Increased Bearing Life
  • NIST Traceable Calibration Certificate Included for Water
Průtokoměry pro vodu - Zobrazit související produkty

Popis

Click on this link if you need more information about a Flow meter.

OMEGA® FTB-201 Series turbine meters have male flared-end fittings for easy connections. They are built to meet the performance requirements of MS 33656, though they do not carry a military specification. These units come with a mating 2-wire connector and can be supplied with the integrally mounted signal conditioners, shown in the to-order table below, to provide 4 to 20 mA, 0 to 5V, and factored pulse outputs.

37° Flare Installation Kits
Proper application of a turbine Installation kits for turbine meters with 37° flare end fittings consist of two lengths of stainless steel tubing cut to a length appropriate for the upstream and downstream straight pipe runs and flared at one end. Mating sleeves and nuts are included. The kits can be conveniently butt-welded into the piping system. Flow straightening sections may be provided with the installation kit. These kits are available in tubing sizes from ½ to 2".

These turbine meters are intended for clean fluid service only; where there is any doubt concerning possible particulate impurities in the process fluid, strainers are recommended. In addition, when using these units for fluids with viscosities other than 1 centistoke, special calibrations and universal viscosity curves are available – consult OMEGA’s sales department.

Ranges
Model
Linear Flow
Range (litres/min)
37° Flare Fittings
Max. Op.
Pressure (Barg)
Length (mm)
Nom. K Factor
Pulses/litre
FTB-201
1.3 to 13.2
¾-16 UNF-3A
344
62
3430
FTB-202
2.8 to 28.4
¾-16 UNF-3A
344
62
2640
FTB-203
4.7 to 36
¾-16 UNF-3A
344
62
1580
FTB-204
6.6 to 60
7/8-14 UNF-3A
344
70
1080
FTB-205
9.5 to 110
1 1/16-12 UNF-3A
344
83
580
FTB-206
15 to 227
1 5/16 -12 UNF-3A
241
89
170
FTB-207
23 to 352
1 5/8 -12 UNF-3A
206
99
110
FTB-208
30 to 492
1 7/8 -12 UNF-3A
155
111
60
FTB-209
57 to 850
2½-12 UNF-3A
120
121
32


Specifications
Accuracy: ±0.5% of reading
Repeatability: ±0.1% of reading
Temperature Range: -268 to 232°C
Maximum Intermittent Overrange: 150% of maximum range
Materials of Construction:
   Body: 304 SS
   Rotor: 17-4 PH SS
   Bearings: 440C SS
Installation Kits: 340 SS, 1.7 mm thick
Electrical: Two-wire connector included
Max Pressure Drop: 0.34 bar

Tabulka pro objednání(Vyberte si model a zadejte počet kusů)
Číslo modelu/ Popis
Kusů
RoHS
Popis
FTB-201 Star
36,150Kč
Dostupnost: 10 týdny
V souladu s RoHS
Linear range water 1.3 to 13.2 l/m; End conections: 3/4-16UNF-3A liquid turbine flowmeters
FTB-202 Star
36,150Kč
Dostupnost: 10 týdny
V souladu s RoHS
Linear range water 2.8 to 28.5 l/m; End conections: 3/4-16UNF-3A liquid turbine flowmeters
FTB-203 Star
36,150Kč
Dostupnost: 2 týdny
V souladu s RoHS
Linear range water 4.7 to 36 l/m. End conections: 3/4-16UNF-3A liquid turbine flowmeters
FTB-204 Star
36,150Kč
Dostupnost: 2 týdny
V souladu s RoHS
Linear range water 6.6 to 60 l/m. End conections: 7/8-14 UNF-3A liquid turbine flowmeters
FTB-205 Star
36,150Kč
Dostupnost: 10 týdny
V souladu s RoHS
Linear range water 9.5 to 110 l/m. End conections: 1 1/16-12 UNF-3A liquid turbine flowmeters
FTB-206 Star
39,900Kč
Dostupnost: 2 týdny
V souladu s RoHS
Linear range water 15 to 227 l/m. End conections: 1 5/16-12 UNF-3A liquid turbine flowmeters
FTB-207 Star
42,450Kč
Dostupnost: 10 týdny
V souladu s RoHS
Linear range water 23 to 352 l/m. End conections: 1 5/8 -12 UNF-3A liquid turbine flowmeters
FTB-208 Star
43,650Kč
Dostupnost: 10 týdny
V souladu s RoHS
Linear range water 30 to 492 l/m. End conections: 1 7/8 -12 UNF-3A liquid turbine flowmeters
FTB-209 Star
51,450Kč
Dostupnost: 10 týdny
V souladu s RoHS
Linear range water 57 to 850 l/m. End conections: 2 1/2 -12 UNF-3A liquid turbine flowmeters
Signal conditioners. Order as a system if purchased with a turbine meter. Eg: SYS/FTB-201/FLSC-18B. Use table below to order
FLSC-18B Star
Konzultujte s prodejním oddělením  
Dostupnost: 
 
V souladu s RoHS
Signal Conditioner 4-20mA output requires 8-40V dc
FLSC-34 Star
Konzultujte s prodejním oddělením  
Dostupnost: 
 
V souladu s RoHS
Signal Conditioner 4-20mA output requires 115 V ac
FLSC-28 Star
Konzultujte s prodejním oddělením  
Dostupnost: 
 
V souladu s RoHS
Signal Conditioner 0-5 V output requires 8-40V dc
FLSC-35B Star
Konzultujte s prodejním oddělením  
Dostupnost: 
 
V souladu s RoHS
Signal Conditioner 0-5 V output requires 115 V ac
FLSC-51 Star
Konzultujte s prodejním oddělením  
Dostupnost: 
 
V souladu s RoHS
Signal Conditioner Square Wave output requires 8-35 V dc
Installation Kits
FTB-K3 Star
9,600Kč
Dostupnost: 9 týdny
V souladu s RoHS
37 Degree Flare Installation Kits for FTB-201, FTB-202, FTB-203. 10" Inlet/5" Outlet Length
FTB-K4 Star
10,800Kč
Dostupnost: 2 týdny
V souladu s RoHS
37 Degree Flare Installation Kit for FTB-204. 10" Inlet/5" Outlet Length
FTB-K5 Star
13,200Kč
Dostupnost: 9 týdny
V souladu s RoHS
37 Degree Flare Installation Kit for FTB-205. 10" Inlet/5" Outlet Length
FTB-K6 Star
13,200Kč
Dostupnost: 9 týdny
V souladu s RoHS
37 Degree Flare Installation Kit for FTB-206. 10" Inlet/5" Outlet Length
FTB-K7 Star
17,100Kč
Dostupnost: 9 týdny
V souladu s RoHS
37 Degree Flare Installation Kit for FTB-207. 14" Inlet/6" Outlet Length
FTB-K8 Star
19,800Kč
Dostupnost: 9 týdny
V souladu s RoHS
37 Degree Flare Installation Kit for FTB-208. 17" Inlet/8" Outlet Length
FTB-K9 Star
34,650Kč
Dostupnost: 9 týdny
V souladu s RoHS
37 Degree Flare Installation Kit for FTB-209. 21" Inlet/9" Outlet Length

Objednávání podle čísla modelu

Číslo modelu
Kusů
Číslo modelu
Kusů


Všechny ceny zobrazeny v Kč (bez DPH)
Poznámka: If an integral signal conditioner is required please order as a system. Omega will scale the signal conditioner to the turbine meter.
Example: SYS/FTB-201/FLSC-18B, scaled system includes: Signal Conditioner, Enclosure, Turbine Meter and Fitting. No additional charge- just add the flowmeter and signal conditioner prices together. Use the table below to order